Pinpoint Test A: DTC P2600: Overview
WARNING: This page is about a different car, the 2011 Mercury Milan, 2011 Lincoln MKZ, and 2011 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.
- A1 CHECK THE VOLTAGE TO THE RELAY
- Ignition OFF.
- Disconnect: Auxiliary Coolant Flow Pump Relay.
- Ignition ON.
Measure the voltage between ground and the auxiliary coolant flow pump relay socket, circuit CBK03 (GY).
- Is the voltage greater than 10 volts?
- Yes : CARRY OUT the auxiliary coolant flow pump relay component test. Refer to ENGINE CONTROLS - COMPONENT TESTING -- FUSION HYBRID, MILAN HYBRID & MKZ HYBRID article for component testing. If the relay tests OK, GO to A2.
- No : REPAIR circuit CBK03 (GY) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- A2 CHECK CIRCUIT CH307 (GY/BU) FOR A SHORT TO VOLTAGE
- Ignition OFF.
- Disconnect: PCM C175t.
- Ignition ON.
- Measure the voltage between ground and PCM C175t-42, circuit CH307 (GY/BU), harness side.
- Is any voltage present?
- Yes : REPAIR circuit CH307 (GY/BU) for a short to voltage. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- No : GO to A3.
- A3 CHECK CIRCUIT CH307 (GY/BU) FOR A SHORT TO GROUND
- Ignition OFF.
- Measure the resistance between ground and PCM C175t-42, circuit CH307 (GY/BU), harness side.
- Is the resistance greater than 10,000 ohms?
- Yes : GO to A4.
- No : REPAIR circuit CH307 (GY/BU) for a short to ground. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- A4 CHECK CIRCUIT CH307 (GY/BU) FOR AN OPEN
- Measure the resistance between auxiliary coolant flow pump relay socket, circuit CH307 (GY/BU) and PCM C175t-42, circuit CH307 (GY/BU), harness side.
- Is the resistance less than 5 ohms?
- Yes : GO to A5.
- No : REPAIR circuit CH307 (GY/BU) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- A5 CHECK THE PCM CONNECTION
- Clear the DTCs.
- Disconnect all the PCM connectors.
- Inspect the module connectors for:
- corrosion.
- pushed-out pins.
- incorrectly seated connector.
- Connect and correctly seat all the PCM connectors.
- Operate the system.
- Does the concern return?
- Yes : INSTALL a new PCM. TEST the system for normal operation.
- No : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.