LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 2615 (Engine Mechanical - 3.0L (4V)) >> In-Vehicle Repair >> Valve Cover - LH >> Removal

Valve Cover - LH: Removal

WARNING: This page is about a different car, the 2011 Mercury Milan and 2011 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: During engine repair procedures, cleanliness is extremely important. Any foreign material (including any material created while cleaning gasket surfaces) that enters the oil passages, coolant passages or the oil pan may cause engine failure.
  1. Remove the LH ignition coil-on-plugs. For additional information, refer to ENGINE IGNITION - 3.0L (4V) -- FUSION & MILAN article.
  2. Detach the 3 wiring retainers from the valve cover.
  3. Detach the wiring retainer from the valve cover stud bolt and 1 retainer from the valve cover.
  4. Disconnect the Variable Camshaft Timing (VCT) electrical connector.
  5. Disconnect the Heated Oxygen Sensor (HO2S) electrical connector.
  6. NOTE: Inspect the crankcase ventilation tube and valve cover sealing area. If either a new valve cover or crankcase ventilation tube is required, both components must be installed new.
  7. Remove the 9 bolts, 5 stud bolts and the valve cover.