LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 244 (Generators & Regulators - F250-F550 Super Duty (Diesel With Dual Generators)) >> Generator Specifications

Generator Specifications

WARNING: This page is about a different car, the 2004 Ford Pickup, 2004 Ford F550 Super Duty, 2004 Ford F450 Super Duty, and 2004 Ford Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.
GENERATOR SPECIFICATIONS

Application Specification
Generator Amperage Rating
Upper Generator 140 Amp
Lower Generator 120 Amp
Load Test (1)
With Tester Load (2) (3)
Without Tester Load (4) (5)
No-Load Test (1)(2) 13.0-15.5 Volts
(1) All tests are performed with engine running at 2000 RPM.
(2) All accessories off.
(3) Adjust tester load bank to determine generator output. Minimum output for 140 amp generator is 95 amp, for 120 amp generator is 75 amp, and for 110 amp generator is 65 amp.
(4) Perform this test with engine running, A/C on, blower motor on high speed, and headlamps on high beam.
(5) With accessories on, voltage should increase a minimum of 0.5 volt above base voltage.