- No communication with the HVAC module - Dual Automatic Temperature Control (DATC) or HVAC module - Electronic Manual Temperature Control (EMTC)
|
- Fuse(s)
- Circuitry open
- HVAC module - DATC
or HVAC module - EMTC
communication network
|
|
- Unable to duplicate the customer concern and no DTCs present
|
- HVAC system and/or related components
|
|
|
|
- Circuitry short
- A/C compressor clutch air gap
- A/C cycling switch
- A/C clutch relay
- Blower motor
- Blower motor control
- Blower motor resistor
- Blower motor switch
- PCM
|
|
- The air inlet door is inoperative
|
- Circuitry open/shorted
- Air inlet door actuator
- Air inlet door/linkage damaged, binding or stuck
- HVAC module - EMTC
or HVAC module - DATC
|
|
- Incorrect/erratic direction of airflow from outlets
|
- Circuitry open/shorted
- Mode door actuator
- Mode door/linkage damaged, binding or stuck
- HVAC module - EMTC
or HVAC module - DATC
|
|
- Insufficient, erratic or no heat
|
- Low engine coolant level
- Plugged or partially plugged heater core
- Temperature blend door/actuator
|
|
- The air conditioning (A/C) is inoperative
|
- Fuse(s)
- Circuitry open
- A/C system discharged/low charge
- PCM
- HVAC module - DATC
- HVAC module - EMTC
- A/C clutch relay
- A/C compressor clutch air gap
- A/C clutch field coil
|
|
- The air conditioning (A/C) is always on - A/C compressor does not cycle
|
- Circuitry shorted
- PCM
- A/C clutch relay
- A/C compressor clutch air gap
- A/C low charge protection switch
|
|
- The air conditioning (A/C) is always on - A/C mode always commanded ON
|
- Circuitry shorted
- PCM
- HVAC module - DATC
- HVAC module - EMTC
|
|
- Temperature control is inoperative/does not operate correctly
|
- Circuitry open/shorted
- HVAC module - EMTC
- HVAC module - DATC
- Temperature blend door is binding or stuck
- Temperature blend door actuator
|
|
- The blower motor is inoperative - EMTC
|
- Fuse(s)
- Circuitry open
- Blower motor switch
- Blower motor relay
- Blower motor
- HVAC module - EMTC
|
|
- The blower motor does not operate correctly - EMTC
|
- Circuitry open/shorted
- A/C blower motor resistor
- A/C blower motor switch
|
|
- The blower motor is inoperative - DATC
|
- Fuse(s)
- Circuitry short/open
- Blower motor relay
- Blower motor
- Blower motor speed control module
- HVAC module - DATC
|
|
- The blower motor does not operate correctly - DATC
|
- Circuitry open/shorted
- Blower motor speed control module
- HVAC module - DATC
|
|
- The dual temperature control is inoperative/does not operate correctly
|
- Temperature blend door/actuator broken/binding
- HVAC module - DATC
- Low A/C refrigerant charge
|
|
- The temperature set point does not repeat after turning the ignition switch OFF
|
- Fuse
- Circuitry short/open
- HVAC module - DATC
|
- VERIFY Smart Junction Box (SJB) fuse 15 (10A) is OK. If OK, CHECK circuit SBP15 (WH/RD) for a short or open and REPAIR as necessary. TEST the system for normal operation. If OK, INSTALL a new HVAC module. REFER to
CLIMATE CONTROL
. TEST the system for normal operation.
|
- The temperature display will not switch between Celsius and Fahrenheit
|
- HVAC module - DATC
- Instrument Cluster (IC)
|
- If the IC
does not switch between English and Metric, REFER to
INSTRUMENT CLUSTER AND PANEL ILLUMINATION
and diagnose.
- If only the HVAC module - DATC
does not switch between English and Metric, INSTALL a new HVAC module. REFER to
CLIMATE CONTROL
. TEST the system for normal operation.
|
- Inaccurate external temperature display
|
- HVAC module - DATC
- Ambient temperature sensor
|
- REFER to DESCRIPTION AND OPERATION of the HVAC module - DATC
External Temperature Display. If the external temperature display is not operating as described and no DTC is present, INSTALL a new ambient temperature sensor. TEST the system for normal operation. If the condition returns again, INSTALL a new HVAC module. REFER to
CLIMATE CONTROL
. TEST the system for normal operation.
|