P0130 - O2 Circuit (Bank 1, Sensor 1)

WARNING: This page is about a different car, the 2010 Mercury Mariner and 2010 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
P0130 - O2 CIRCUIT (BANK 1, SENSOR 1)

Description:  The powertrain control module (PCM) monitors the heated oxygen sensor (HO2S) for a circuit concern. The test fails when the PCM detects a concern with one of the circuits used to determine the oxygen content in the exhaust gas.
Possible Causes: 
  • Open UO2S circuit
  • Open UO2SGREF circuit
  • UO2S circuit short to voltage or ground
  • UO2SGREF circuit short to voltage or ground
  • UO2SPC circuit short to voltage or ground
  • UO2SPCT circuit short to voltage or ground
  • Damaged universal HO2S
Diagnostic Aids: 
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All - GO to PINPOINT TEST DZ . GO to PINPOINT TEST DZ .