P0481 - Fan 2 Control Circuit
WARNING: This page does not describe the selected car, but rather 32 other vehicles, including the 2008 Mercury Sable, 2008 Mercury Mountaineer, 2008 Mercury Milan, 2008 Mercury Mariner, and 2008 Mercury Grand Marquis. However, it is still accessible from the selected car via links, so may be relevant.
P0481 - FAN 2 CONTROL CIRCUIT
| Description: | Monitors the HFC primary circuit output from the powertrain control module (PCM). The test fails, when the HFC output is commanded on (grounded) and excessive current draw is detected on the HFC circuit; or when the HFC circuit is commanded off and voltage is not detected on the HFC circuit (the PCM expects to detect VPWR voltage through the high speed FC relay coil to the HFC circuit). | |||
| Possible Causes: |
|
|||
| Diagnostic Aids: | When the HFCF PID reads YES, a concern is currently present. An open circuit or short to ground can only be detected when the PCM is not grounding the HFC circuit. A short to voltage can only be detected when the PCM is grounding the HFC circuit. During the key on engine off (KOEO) and key on engine running (KOER) self-test, the HFC circuit is cycled on and off. | |||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory | |
| All | refer to PINPOINT TEST KF . | |||