P1408 - Exhaust Gas RECIRCULATION (EGR) Flow Out Of Self-Test Range
WARNING: This page is about a different car, the 2007 Mercury Mariner and 2007 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
P1408 - EXHAUST GAS RECIRCULATION (EGR) FLOW OUT OF SELF-TEST RANGE
| Description: | This test is carried out during the key on engine running (KOER) on-demand self-test only. The EGR system is commanded on at a fixed engine speed. The test does not pass and the DTC is set when the measured EGR flow falls above or below the required calibration. | |||
| Possible Causes: | See possible causes for DTC P0400. | |||
| Diagnostic Aids: | For EEGR, use the output state control function of the scan tool and monitor the MAP PID (MAP) and the EEGR PID (EGRMDSD) while commanding the EEGR on. If EGR is introduced into the engine at idle, the RPM drops or stalls out. | |||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory | |
| All | - | refer to PINPOINT TEST KD . | - | |