Removal And Installation

WARNING: This page is about a different car, the 2007 Lincoln Mark LT and 2007 Ford Pickup. However, it is still accessible from the selected car via links, so may be relevant.
  1. Disconnect the positive crankcase ventilation (PCV) tube quick connect coupling. For additional information, refer to FUEL SYSTEM - GENERAL INFORMATION article.
  2. Disconnect the PCV valve electrical connector.
  3. Rotate the PCV valve counterclockwise and remove the PCV valve.
    • Discard the PCV valve.
  4. To install, reverse the removal procedure.