Pinpoint Test F: A Single Illumination Source Is Inoperative - NONDIMMABLE Illumination Source
- F1 CHECK CIRCUIT CBP02 (GN) FOR VOLTAGE
- Disconnect: Inoperable Illumination Source.
- Key in ON position.
- Measure the voltage between the inoperable illumination source harness side and ground as follows:CONNECTOR - PIN CIRCUIT
Illumination Source Connector - Pin Circuit LH door lock control switch (Fusion/Milan) C505-2 CBP02 (GN) RH door lock control switch (Fusion/Milan) C605-2 CBP02 (GN) Ashtray C370-2 CBP02 (GN) Roof Opening Panel Switch C912-1 CBP02 (GN) - Is the voltage greater than 10 volts?
Yes : For door lock control switch(es), INSTALL a new door lock control switch. REFER to HANDLES, LOCKS, LATCHES AND ENTRY SYSTEMS .
For : the ashtray, GO to F3.
For : the roof opening panel, GO to F4.
No : GO to F2.
- F2 CHECK CIRCUIT CBP02 (GN) FOR AN OPEN
- Key in OFF position.
- Disconnect: SJB C2280e.
- Measure the resistance between the SJB C2280e-25, circuit CBP02 (GN) harness side; and the inoperable illumination source as follows:CONNECTOR - PIN CIRCUIT
Illumination Source Connector - Pin Circuit LH door lock control switch (Fusion/Milan) C505-2 CBP02 (GN) RH door lock control switch (Fusion/Milan) C605-2 CBP02 (GN) Ashtray C370-2 CBP02 (GN) Roof Opening Panel Switch C912-1 CBP02 (GN) - Is the resistance less than 5 ohms?
Yes : GO to F7.
No : REPAIR the circuit. TEST the system for normal operation.
- F3 CHECK CIRCUIT GD115 (BK/GY) FOR AN OPEN
- Measure the resistance between the ashtray C370-3, circuit GD115 (BK/GY), harness side and ground.
- Is the resistance less than 5 ohms between the ashtray and ground?
Yes : INSTALL a new illumination source. TEST the system for normal operation.
No : REPAIR the circuit. TEST the system for normal operation.
- F4 CHECK CIRCUIT CPR39 (VT/WH) FOR AN OPEN
- Disconnect: Roof Opening Panel Module C921.
- Measure the resistance between the roof opening panel switch C912-4, circuit CPR39 (VT/WH), harness side and the roof opening panel module C921-11, circuit CPR39 (VT/WH), harness side.
- Is the resistance less than 5 ohms?
Yes : GO to F5.
No : REPAIR the circuit. TEST the system for normal operation.
- F5 CHECK CIRCUIT GD139 (BK/YE) FOR AN OPEN
- Measure the resistance between the roof opening panel module C921-4, circuit GD139 (BK/YE), harness side and ground.
- Is the resistance less than 5 ohms?
Yes : GO to F6.
No : REPAIR the circuit. TEST the system for normal operation.
- F6 CHECK FOR CORRECT ROOF OPENING PANEL MODULE OPERATION
- Disconnect the roof opening panel module connector.
- Check for:
- Corrosion
- Pushed-out pins
- Connect the roof opening panel module connector and make sure it seats correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
Yes : INSTALL a new roof opening panel module. REFER to ROOF OPENING PANEL . TEST the system for normal operation.
No : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
- F7 CHECK FOR CORRECT SJB OPERATION
- Disconnect all the SJB connectors.
- Check for:
- Corrosion
- Pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
Yes : INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC CONTROL MODULES . TEST the system for normal operation.
No : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.