Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1770 (Instrument Cluster And Panel Illumination) >> Diagnosis And Testing >> Instrument Cluster and Panel Illumination >> Pinpoint Tests >> Pinpoint Test F: A Single Illumination Source Is Inoperative - Non-Dimmable Illumination Source >> Pinpoint Test F: A Single Illumination Source Is Inoperative - NONDIMMABLE Illumination Source

Pinpoint Test F: A Single Illumination Source Is Inoperative - NONDIMMABLE Illumination Source

WARNING: This page is about a different car, the 2006 Mercury Milan, 2006 Lincoln Zephyr, and 2006 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION: Use the correct probe adaptor(s) when making measurements. Failure to use the correct probe adaptor(s) may damage the connector.
  1. F1 CHECK CIRCUIT CBP02 (GN) FOR VOLTAGE 
    • Disconnect: Inoperable Illumination Source.
    • Key in ON position.
    • Measure the voltage between the inoperable illumination source harness side and ground as follows:
      CONNECTOR - PIN CIRCUIT

      Illumination Source Connector - Pin Circuit
      LH door lock control switch (Fusion/Milan) C505-2 CBP02 (GN)
      RH door lock control switch (Fusion/Milan) C605-2 CBP02 (GN)
      Ashtray C370-2 CBP02 (GN)
      Roof Opening Panel Switch C912-1 CBP02 (GN)
    • Is the voltage greater than 10 volts? 

    Yes  : For door lock control switch(es), INSTALL a new door lock control switch. REFER to HANDLES, LOCKS, LATCHES AND ENTRY SYSTEMS .

    For  : the ashtray, GO to  F3.

    For  : the roof opening panel, GO to  F4.

    No  : GO to F2.

  2. F2 CHECK CIRCUIT CBP02 (GN) FOR AN OPEN 
    • Key in OFF position.
    • Disconnect: SJB C2280e.
    • Measure the resistance between the SJB C2280e-25, circuit CBP02 (GN) harness side; and the inoperable illumination source as follows:
      CONNECTOR - PIN CIRCUIT

      Illumination Source Connector - Pin Circuit
      LH door lock control switch (Fusion/Milan) C505-2 CBP02 (GN)
      RH door lock control switch (Fusion/Milan) C605-2 CBP02 (GN)
      Ashtray C370-2 CBP02 (GN)
      Roof Opening Panel Switch C912-1 CBP02 (GN)
    • Is the resistance less than 5 ohms? 

    Yes  : GO to  F7.

    No  : REPAIR the circuit. TEST the system for normal operation.

  3. F3 CHECK CIRCUIT GD115 (BK/GY) FOR AN OPEN 
    • Measure the resistance between the ashtray C370-3, circuit GD115 (BK/GY), harness side and ground.
      Fig 1: Checking Circuit GD115 (BK/GY) For Open
      G04682626Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms between the ashtray and ground? 

    Yes  : INSTALL a new illumination source. TEST the system for normal operation.

    No  : REPAIR the circuit. TEST the system for normal operation.

  4. F4 CHECK CIRCUIT CPR39 (VT/WH) FOR AN OPEN 
    • Disconnect: Roof Opening Panel Module C921.
    • Measure the resistance between the roof opening panel switch C912-4, circuit CPR39 (VT/WH), harness side and the roof opening panel module C921-11, circuit CPR39 (VT/WH), harness side.
      Fig 2: Checking Circuit CPR39 (VT/WH) For Open
      G04682627Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 

    Yes  : GO to F5.

    No  : REPAIR the circuit. TEST the system for normal operation.

  5. F5 CHECK CIRCUIT GD139 (BK/YE) FOR AN OPEN 
    • Measure the resistance between the roof opening panel module C921-4, circuit GD139 (BK/YE), harness side and ground.
      Fig 3: Checking Circuit GD139 (BK/YE) For Open
      G04682628Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 

    Yes  : GO to F6.

    No  : REPAIR the circuit. TEST the system for normal operation.

  6. F6 CHECK FOR CORRECT ROOF OPENING PANEL MODULE OPERATION 
    • Disconnect the roof opening panel module connector.
    • Check for:
      • Corrosion
      • Pushed-out pins
    • Connect the roof opening panel module connector and make sure it seats correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 

    Yes  : INSTALL a new roof opening panel module. REFER to ROOF OPENING PANEL . TEST the system for normal operation.

    No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.

  7. F7 CHECK FOR CORRECT SJB OPERATION 
    • Disconnect all the SJB connectors.
    • Check for:
      • Corrosion
      • Pushed-out pins
    • Connect all the SJB connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 

    Yes  : INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC CONTROL MODULES . TEST the system for normal operation.

    No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.