Evaporative Emission Repair Verification Drive Cycle
WARNING: This page is about a different car, the 2006 Mercury Montego, 2006 Ford Freestyle, and 2006 Ford Five Hundred. However, it is still accessible from the selected car via links, so may be relevant.
SPECIAL TOOL(S)
| Worldwide Diagnostic System (WDS) Vehicle Communication Module (VCM) with appropriate adapters, or equivalent diagnostic tool |
Drive Cycle Recommendations
NOTE:
The following procedure is designed to execute and complete the evaporative emission (EVAP) repair verification drive cycle and to clear the Ford P1000, inspection and maintenance (I/M) readiness code. When the ambient air temperature is below 4.4°C (40°F) or above 37.8°C (100°F), or the altitude is above 2,438 meters (8,000 feet), the EVAP monitor will not run. If the P1000 must be cleared in these conditions, the powertrain control module (PCM) must detect them once (twice on some applications) before the EVAP monitor can be bypassed and the P1000 cleared. The EVAP bypassing procedure is described in the following drive cycle.
- Most OBD II monitors will complete more readily using a steady foot driving style during cruise or acceleration modes. Operating the throttle in a smooth fashion will minimize the time necessary for monitor completion.
- Fuel tank level should be between 1/2 and 3/4 full with 3/4 full being the most desirable.
- The evaporative monitor can only operate during the first 30 minutes of engine operation. When executing the procedure for this monitor, stay in part throttle mode and drive in a smooth fashion to minimize fuel slosh.
Drive Cycle Preparation
NOTE: For best results, follow each of the following steps as accurately as possible. - Install the diagnostic tool. Turn the key ON with the engine OFF. Cycle the key off, then on. Select the appropriate vehicle and engine qualifier. Clear all diagnostic trouble codes (DTCs) and carry out a PCM reset.
- Begin to monitor the following PIDs: ECT, EVAPDC, FLI (if available) and TP MODE. Press Diagnostic Data Link, PCM, PID/Data monitor and record, press trigger to select each PID, then start.
- Start the engine without returning the key to the OFF position.
Preparation for Monitor Entry
WARNING: Strict observance of posted speed limits and attention to driving conditions are mandatory when proceeding through the following drive cycle. - Idle the vehicle for 15 seconds. Drive at 64 km/h (40 mph) until the ECT is at least 76.7°C (170°F).
- Is IAT above 4.4°C (40°F) and below 37.8°C (100°F)? If not, continue with the following steps but note that the EVAP Monitor Bypass portion of the drive cycle (Step 13) will be required to bypass the EVAP monitor and clear the P1000.
- Cruise at 64 km/h (40 mph) for 60 seconds.
- This executes the EVAP monitor if IAT is above 4.4°C (40°F) and below 37.8°C (100°F).
- To initiate the monitor, TP MODE should equal PT, EVAPDC must be greater than 75%, and FLI must be between 15 and 85%.
- Avoid sharp turns and hills.
- Cruise at 72 to 104 km/h (45 to 65 mph) for 10 minutes.
- Bring the vehicle to a stop. Idle with the transmission in DRIVE (for automatic transmission) or NEUTRAL (for manual transmission) for 2 minutes.
- Using the diagnostic tool, check for pending codes. Conduct normal repair procedures for any pending code concerns. Rerun any incomplete monitor.
- This allows the bypass counter to increment to 2.
- Do not repeat Step 4.
- Park the vehicle for a minimum of 8 hours. Repeat Steps 5 through 12.
NOTE:
This step bypasses the engine soak timer and resets OBD II monitor status.
NOTE:
This step allows engine warm-up and provides intake air temperature (IAT) input to the PCM.
NOTE:
This step executes the heated oxygen sensor (HO2S) monitor.
NOTE:
NOTE:
This step executes the ISC portion of the Secondary Air/CCM.
Pending Code and EVAP Monitor Bypass Check
NOTE:
EVAP Monitor Bypass
NOTE: