Pinpoint Test F: Drumming Noise
WARNING: This page is about a different car, the 2006 Mercury Grand Marquis and 2006 Ford Crown Victoria. However, it is still accessible from the selected car via links, so may be relevant.
- F1 CHECK THE EXHAUST SYSTEM
- With the vehicle in NEUTRAL, position it on a hoist. Refer to JACKING & LIFTING .
- Key in START position.
- Increase the engine rpm until the noise is the loudest. Note the engine rpm.
- Key in OFF position.
- Add approximately 9 kg (20 lb) of weight to the exhaust system. First place the weight at the tail pipe and test, then at the front pipe.
- Key in START position.
- Increase the engine rpm and listen for the drumming noise. Note the engine rpm if the noise occurs.
- Key in OFF position.
- Using a vibration analyzer (VA), determine the amount of vibration that occurs with the drumming noise.
- Is the noise/vibration reduced or eliminated, or does the noise/vibration occur at a different rpm?
WARNING: If equipped with fire suppression system, depower the system. For important safety warnings and procedures, refer to FIRE SUPPRESSION SYSTEM .Yes : CARRY OUT EXHAUST SYSTEM NEUTRALIZING . TEST the system for normal operation. If equipped with fire suppression system, GO to F3.
No : GO to F2.
- F2 POWERTRAIN/DRIVETRAIN MOUNT NEUTRALIZING
- Carry out POWERTRAIN/DRIVETRAIN MOUNT NEUTRALIZING . Test the system for normal operation.
- Is the noise reduced or eliminated?
Yes : Vehicle OK. TEST the system for normal operation. If equipped with fire suppression system, GO to F3.
No : CONDUCT diagnosis of other suspect components. If equipped with fire suppression system, GO to F3.
- F3 REPOWER THE FIRE SUPPRESSION SYSTEM
- Verify that the fire suppression system is repowered. For additional information, refer to FIRE SUPPRESSION SYSTEM .
- Is the fire suppression system repowered?
WARNING: If equipped with fire suppression system, repower the system. For important safety warnings and procedures, refer to FIRE SUPPRESSION SYSTEM .Yes : Fire suppression system repowering is complete.
No : REFER to FIRE SUPPRESSION SYSTEM for fire suppression system depowering and repowering procedure.