LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 132 (Instrument Panel - Analog - BLACKWOOD) >> System Tests >> Test D: Oil Pressure Gauge Inaccurate Or Indicator Is Always On

Test D: Oil Pressure Gauge Inaccurate Or Indicator Is Always On

WARNING: This page is about a different car, the 2002 Lincoln Blackwood. However, it is still accessible from the selected car via links, so may be relevant.
  1. Turn ignition switch to LOCK position. Disconnect engine oil pressure switch harness connector. Turn ignition switch to RUN position. Connect fused jumper wire (5-amp) between engine oil pressure switch harness connector and ground. Oil pressure gauge should indicate normal oil pressure with jumper wire connected and no oil pressure with jumper wire disconnected. If oil pressure gauge operation is not as specified, go to next step. If oil pressure gauge operates as specified, replace engine oil pressure switch. See ENGINE OIL PRESSURE SWITCH  under REMOVAL & INSTALLATION.
  2. Turn ignition switch to LOCK position. Disconnect instrument cluster 20-pin harness connector C220a. Measure resistance in White/Red wire between engine oil pressure switch harness connector and instrument cluster 20-pin harness connector C220a terminal No. 20. Measure resistance in White/Red wire between instrument cluster 20-pin harness connector terminal No. 20 and ground. See Figure. Resistance should be 5 ohms or less between instrument cluster 20-pin harness connector and oil pressure switch harness connector, and more than 10 k/ohms between instrument cluster 20-pin harness connector and ground. If resistance is as specified, go to next step. If resistance is not as specified, repair open or short to ground in White/Red wire between oil pressure switch harness connector and instrument cluster.
  3. Disconnect all instrument cluster harness connectors. Inspect harness connectors for corrosion and pushed out pins. Connect all instrument cluster harness connectors, ensuring they are connected correctly. Operate system and verify if concern is still present. If concern is still present, replace instrument cluster. See INSTRUMENT CLUSTER  under REMOVAL & INSTALLATION. If concern is not present, system is operating correctly at this time.