LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1287 (Instrument Cluster) >> Diagnosis And Testing >> Instrument Cluster >> Pinpoint Test O: The Anti-Lock Brake System (ABS) Warning Indicator Is Never On >> Pinpoint Test O: The Anti-Lock Brake System (Abs) Warning Indicator Is Never On

Pinpoint Test O: The Anti-Lock Brake System (Abs) Warning Indicator Is Never On

WARNING: This page is about a different car, the 2005 Lincoln LS. However, it is still accessible from the selected car via links, so may be relevant.
  1. O1 CARRY OUT THE INSTRUMENT CLUSTER ANTI-LOCK BRAKE SYSTEM (ABS) WARNING INDICATOR ACTIVE COMMAND USING THE DIAGNOSTIC TOOL 
    • Key in ON position.
    • Enter the following diagnostic mode on the diagnostic tool: Instrument Cluster Active Command.
    • Select the instrument cluster warning lamps and chime active command. Trigger the all lamps active command on. Observe the ABS warning indicator.
    • Does the ABS warning indicator illuminate? 
    • Yes  : GO to  O2.
    • No  : GO to  O3.
  2. O2 CHECK FOR CORRECT ABS MODULE OPERATION 
    • Disconnect the ABS module connector.
    • Check for:
      • corrosion
      • pushed-out pins
    • Connect the ABS module connector and make sure it seats correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new ABS module. REFER to ANTI-LOCK CONTROL . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
  3. O3 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION 
    • Disconnect all the instrument cluster connectors.
    • Check for:
    • corrosion
    • pushed-out pins
    • Connect all the instrument cluster connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER  in this article. TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.