LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1102 (Instrument Cluster System) >> Diagnosis And Testing >> Instrument Cluster >> Pinpoint Test P: The Traction Control Indicator Is Never/Always On >> Testing

Pinpoint Test P: The Traction Control Indicator Is Never/Always On: Testing

WARNING: This page is about a different car, the 2005 Mercury Montego, 2005 Ford Freestyle, and 2005 Ford Five Hundred. However, it is still accessible from the selected car via links, so may be relevant.
  1. P1 CARRY OUT THE INSTRUMENT CLUSTER INDICATOR LAMP ACTIVE COMMAND USING THE DIAGNOSTIC TOOL 
    • Key in ON position.
    • Enter the following diagnostic mode on the scan tool: Instrument Cluster Active Command.
    • Select the instrument cluster warning lamps and chime active command. Trigger the all lamps active command on and off. Observe the traction control indicator.
    • Does the traction control indicator illuminate when triggered on and turn off when triggered off? 
    • Yes  : GO to  P3.
    • No  : GO to P2.
  2. P2 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION 
    • Disconnect the instrument cluster connector.
    • Check for:
      • corrosion
      • pushed-out pins
    • Connect the instrument cluster connector and make sure it seats correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
  3. P3 CHECK FOR CORRECT ABS MODULE OPERATION 
    • Disconnect the ABS module connector.
    • Check for:
      • corrosion
      • pushed-out pins
    • Connect the ABS module connector and make sure it seats correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new ABS module. REFER to ANTI-LOCK CONTROL . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.