Generator Load

WARNING: This page does not describe the selected car, but rather 16 other vehicles, including the 2000 Mercury Villager, 2000 Mercury Mountaineer, 2000 Lincoln Navigator, 2000 Ford Windstar, and 2000 Ford Ranger. However, it is still accessible from the selected car via links, so may be relevant.

The Generator Load Input (GLI) circuit is used by the PCM to determine generator load on the engine. As generator load increases the PCM will adjust idle speed accordingly. This strategy helps reduce idle surges due to switching high current loads. The GLI signal is sent to the PCM from the voltage regulator/generator. The signal is a variable frequency duty cycle. Normal operating frequency is 40 - 250 Hz. Normal signal DC voltage (referenced to ground) is between 1.5 V (low generator load) and 10.5 V (high generator load).