Continuous Memory Codes (Intermittent Faults)
WARNING: This page is about a different variant/trim than selected.
CAUTION:
Continuous memory codes should be recorded when retrieved. These DTCs may be used to identify intermittent faults that exist after all KOEO and KOER DTCs have been repaired. Some continuous memory code faults may not be valid after KOEO and KOER DTCs are serviced.
These DTCs result from information stored by PCM during continuous self-test monitoring. Use these DTCs for diagnosis only when KOEO SELF-TEST and KOER SELF-TEST result in SYSTEM PASS and all steps in QUICK TEST are successfully completed. These DTCs indicate faults previously recorded. Fault may or may not be currently present. See DIAGNOSTIC TROUBLE CODE IDENTIFICATION table. After noting and/or repairing concern, clear codes from memory. See CLEARING DIAGNOSTIC TROUBLE CODES . Intermittent faults may be caused by a sensor, connector or wiring-related concern.
DIAGNOSTIC TROUBLE CODE IDENTIFICATION
| DTC (1) | Code Definition | System Test | ||||
|---|---|---|---|---|---|---|
| P0707 | TR Sensor Circuit Shorted | D | ||||
| P0708 | TR Sensor Circuit Open | D | ||||
| P0712 | TFT Sensor Circuit Shorted | B | ||||
| P0713 | TFT Sensor Circuit Open | B | ||||
| P0715 | Insufficient Input From TSS Sensor | F | ||||
| P0717 | No TSS Sensor Signal Detected | F | ||||
| P0718 | TSS Sensor Circuit Intermittent | F | ||||
| P0720 | Insufficient OSS Sensor Signal | F | ||||
| P0721 | Noisy OSS Sensor Signal | F | ||||
| P0722 | OSS Sensor Signal Intermittent | F | ||||
| P0731 | No 1st Gear | A | ||||
| P0732 | No 2nd Gear | A | ||||
| P0733 | No 3rd Gear | A | ||||
| P0734 | No 4th Gear | A | ||||
| P0743 | TCC Circuit Error | C | ||||
| P0750 | SS1 Solenoid Circuit Failure | A | ||||
| P0751 | SS1 Functional Failure | A | ||||
| P0755 | SS2 Solenoid Circuit Failure | A | ||||
| P0756 | SS2 Functional Failure | A | ||||
| P1702 | TR Sensor Circuit Intermittent | D | ||||
| P1705 | TR Sensor Not In Park | D | ||||
| P1711 | TFT Sensor Out Of Range | B | ||||
| P1713 | TFT Sensor In Low Failure | B | ||||
| P1714 | SS1 Mechanical Failure Detected | (2) | ||||
| P1715 | SS2 Mechanical Failure Detected | (2) | ||||
| P1718 | TFT Sensor In High Failure | B | ||||
| P1742 | TCC Solenoid Failed On | C | ||||
| P1744 | TCC/Excessive Slip Detected | C | ||||
| P1746 | Open PCM Output Driver | E | ||||
| P1747 | EPC Solenoid Circuit Failure | E | ||||
| P1751 | SS1 Functional Failure | A | ||||
| P1756 | SS2 Functional Failure | A | ||||
| P1783 | Transaxle Overheating | B | ||||
| P1788 | 3-2T/CCS Solenoid Circuit Failure | G | ||||
| P1789 | 3-2T/CCS Solenoid Circuit Failure | G | ||||
|
||||||