LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.0 3, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 814 (Automatic Transmission - 4R70W, 4R75W) >> Diagnosis And Testing >> Leakage Inspection >> Notes

Leakage Inspection: Notes

WARNING: This page is about a different car, the 2005 Ford RV Cutaway, 2005 Ford Econoline, and 2005 Ford Cutaway. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: An ultraviolet light must be used to detect the fluorescent dye solution.
  1. Add UV Fluorescent Tracer Dye (164-R3701 or equivalent specifically for ATF) to the automatic transmission fluid. Use 30 ml (1 ounce) of dye solution for every 3.8 liters (4 quarts) of ATF capacity. Add any additional transmission fluid, designated for this transmission/transaxle, to bring the unit to the correct fluid level.
  2. Start and run the engine. Shift the transmission through all gears several times to make sure that the fluorescent dye has had time to circulate. Observe the back of the engine, cylinder block and the top of the converter housing part of the case for evidence of fluid leakage. Turn off the engine.
  3. Raise the vehicle on a hoist.
  4. NOTE: The leak source will probably be above and/or forward of the actual leak indication, due to airflow and/or gravity.
  5. Using an ultraviolet light, observe the transmission for possible leaks. Following the leak back to its source point, repair the leak as required.
EXTERNAL FLUID LEAKS

Leak Path Possible Source
Leaks at the fluid pan-to-case fittings
  • Pan bolts not tightened to specification.
  • Pan gasket damaged.
  • Case pan rail damaged.
Fluid cooler lines or fittings leaking
  • Cooler line(s), cooler line fitting(s) damaged.
  • Cooler line fitting-to-case union damaged.
  • Case damage at case fitting.
Fluid cooler line nut-to-case fittings leaking
  • Damaged or missing O-ring seals.
  • Fitting(s) not tightened to specification.
Leaks at the fluid cooler
  • Fluid cooler damage.
  • Fitting(s) damaged or not tightened to specification.
Leaks at external sensors
  • Damaged or missing O-ring seals.
  • Screw not tightened to specification.
Leaks at the manual control lever seal
  • Damaged or missing lever seal.
Leaks at the solenoid body harness connector
  • Solenoid body harness connector O-ring seal(s), either on the harness end or the solenoid body, damaged or missing.
Fluid leakage in the torque converter area