Home >> Ford >> 2000 >> Contour SE, 2.0 3, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 765 (Engine Controls - Powertrain DTC Charts & Description (Except Diesel & Hybrid)) >> Diagnostic Trouble Code (DTC) Charts And Descriptions >> DTC P0480: Low Fan Control (LFC)/Fan Control 1 (FC1) Primary Circuit Malfunction

DTC P0480: Low Fan Control (LFC)/Fan Control 1 (FC1) Primary Circuit Malfunction

WARNING: This page does not describe the selected car, but rather 32 other vehicles, including the 2005 Mercury Sable, 2005 Mercury Mountaineer, 2005 Mercury Monterey, 2005 Mercury Montego, and 2005 Mercury Mariner. However, it is still accessible from the selected car via links, so may be relevant.
P0480 - LOW FAN CONTROL (LFC)/FAN CONTROL 1 (FC1) PRIMARY CIRCUIT MALFUNCTION

For Relay Controlled Electric Cooling Fan 
Description:  Monitors the LFC or fan control (FC) for 1 speed fan applications, primary circuit output from the powertrain control (PCM). The test fails when the PCM grounds the LFC/FC circuit and excessive current draw is detected on the LFC/FC circuit; or with the LFC/FC circuit not grounded by the PCM the voltage is not detected on the LFC/FC circuit (the PCM expects to detect VPWR voltage coming through the low speed FC relay coil to the LFC/FC circuit)
Possible Causes: 
  • Open or shorted LFC/FC circuit
  • Open VPWR circuit to the low speed FC relay
  • Damaged low speed FC relay
Diagnostic Aids:  When the LFCF PID reads YES, a fault is currently present. During the key on, engine off (KOEO) self-test, the cooling fan is cycled on and off. A short to voltage can only be detected when the PCM is grounding the LFC/FC circuit. During the KOEO and key on, engine running (KOER) self-test, the LFC/FC circuit is cycled on and off.
For Variable Speed Electric Cooling Fan 
Description:  This test checks the fan control-variable (FCV) output circuit. The DTC sets if the powertrain control module (PCM) detects the voltage on the FCV circuit is not within the expected range.
Possible Causes: 
  • FCV circuit open or shorted
  • B+ or ground circuit fault to cooling fan
  • VPWR open to cooling fan (if applicable)
  • Damaged cooling fan module
  • Damaged PCM
Diagnostic Aids:  During the key on, engine off (KOEO) self-test, the cooling fan is cycled on and off.
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
Freestar/Monterey GO to KF: Fan Control (FC) Relays STEP KF16. GO to KF: Fan Control (FC) Relays STEP KF16. GO to KF: Fan Control (FC) Relays STEP KF49.
Crown Victoria, Grand Marquis, Town Car, Five Hundred, Freestyle, Montego GO to KN: Variable Speed Electric Cooling Fan STEP KN1. GO to KN: Variable Speed Electric Cooling Fan STEP KN1. GO to KN: Variable Speed Electric Cooling Fan STEP KN7.
LS, Thunderbird GO to KN: Variable Speed Electric Cooling Fan STEP KN12. GO to KN: Variable Speed Electric Cooling Fan STEP KN12. GO to KN: Variable Speed Electric Cooling Fan STEP KN19.