Pinpoint Test L: The Tachometer Is Inoperative
WARNING: This page is about a different car, the 2004 Lincoln LS. However, it is still accessible from the selected car via links, so may be relevant.
- L1 RETRIEVE THE RECORDED DTCS FROM BOTH CONTINUOUS AND ON-DEMAND SELF-TESTS - POWERTRAIN CONTROL MODULE (PCM)
- Use the recorded PCM DTCs from the continuous and on-demand self-test.
- Are any DTCs recorded?
- Yes : REPAIR the DTC. REFER to the ENGINE CONTROLS - POWERTRAIN DTC CHARTS & DESCRIPTIONS - CNG, FLEX-FUEL & GASOLINE article in ENGINE PERFORMANCE .
- No : GO to L2.
- L2 CARRY OUT THE INSTRUMENT CLUSTER TACHOMETER ACTIVE COMMAND USING THE DIAGNOSTIC TOOL
- Connect the diagnostic tool.
- Key in ON position.
- Enter the following diagnostic mode on the diagnostic tool: Instrument Cluster Active Command.
- Select the instrument cluster TACHOMETER CONTROL active command. Trigger the TACHOMETER active command. Adjust the scroll knob until TACHOMETER reads 50%. Note the tachometer gauge reading.
- Adjust the scroll knob until TACHOMETER reads 100%. Note the tachometer gauge reading.
- Does the tachometer gauge needle start at 0 RPM, move to approximately 3500 RPM at 50% and 7000 RPM at 100%?
- Yes : GO to L4.
- No : GO to L3.
- L3 CHECK FOR CORRECT PCM OPERATION
- Disconnect all the PCM connectors.
- Check for:
- corrosion
- pushed-out pins
- Connect all the PCM connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes : INSTALL a new PCM. REFER to INTAKE AIR, FUEL CHARGING, STARTING & ENGINE ELECTRONICS - 3.0L (4V) or INTAKE AIR, FUEL CHARGING, STARTING & ENGINE ELECTRONICS - 3.9L . TEST the system for normal operation.
- No : The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. CLEAR the DTCs. TEST the system for normal operation.
- L4 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION
- Disconnect all the instrument cluster connectors.
- Check for:
- corrosion
- pushed-out pins
- Connect all the instrument cluster connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes : INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER . TEST the system for normal operation.
- No : The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test.