Mustang Cobra 4.6L 4V SVT Supercharged
WARNING: This page does not describe the selected car, but rather 30 other vehicles, including the 2004 Mercury Sable, 2004 Mercury Mountaineer, 2004 Mercury Monterey, 2004 Mercury Marauder, and 2004 Mercury Grand Marquis. However, it is still accessible from the selected car via links, so may be relevant.
SENSORS/INPUT - 4.6L 4V MUSTANG SVT COBRA SUPERCHARGED
| Sensors/Inputs | PCM Pin/PID only | Measured/PID Values | Units Measured/PID | |||
|---|---|---|---|---|---|---|
| KOEO | Hot Idle | 30 MPH | 55 MPH | |||
| FEPS | 13 | .5-.6 | .5-.6 | .5-.6 | .5-.6 | DCV |
| CKP (+) | 21 | 0 | 360-420 | 680-800 | 860-950 | Hz |
| 02S12 | 35 | .1 | (D) | (D) | (D) | DCV |
| IAT2 | 37 | 1.7-3.5/120-50 (K) | 1.7-3.5/120-50 (K) | 1.7-3.5/120-50 (K) | 1.7-3.5/120-50 (K) | DCV/DEG |
| ECT | 38 | .4-1/200-160 | .4-1/200-160 | .4-1/200-160 | .4-1/200-160 | DCV/DEG |
| IAT | 39 | 1.7-3.5/120-50 (K) | 1.7-3.5/120-50 (K) | 1.7-3.5/120-50 (K) | 1.7-3.5/120-50 (K) | DCV/DEG |
| FPM | 40 | 2.5-7.5/87-110 | 2.5-7.5/87-110 | 2.5-7.5/87-110 | 2.5-7.5/87-110 | DCV/% |
| ACCS | 41 | .1/OFF | VBAT/ON (A) | .1/OFF | .1/OFF | DCV/OFF-ON |
| O2S11 | 60 | 0 | switching (C) | switching (C) | switching (C) | DCV |
| 02S22 | 61 | 0 | (D) | (D) | (D) | DCV |
| FTP V/FTP (gs) | 62 | 2.6/0 | 2.6/0 | 2.6/0 | 2.6/0 | DCV/IN-H2O |
| FRP V/FRP | 63 | 3.3/40 | 2.8/39 | 2.8/39 | 2.8/39 | DCV/PSI |
| DPFEGR | 65 | .25-1.3 | .25-1.3 | .25-4.65 | .25-4.65 | DCV |
| OSS | 84 | 0 | 0 | 270/1365 | 470/2440 | Hz/RPM |
| CID | 85 | 0 | 5-7 | 9-12 | 11-14 | Hz |
| ACP | 86 | VBAT/OPEN | VBAT/OPEN | VBAT/OPEN | VBAT/OPEN | DCV/OPEN-CLOSED |
| 02S21 | 87 | 0 | switching (C) | switching (C) | switching (C) | DCV |
| MAF V | 88 | 0 | .5-.8 | .8-1.3 | 1.2-1.7 | DCV |
| TP V | 89 | .53-1.27 | .53-1.27 | .9-1.2 | 1-1.3 | DCV |
| BPP | 92 | .1/OFF | VBAT/ON (E) | .1/OFF | .1/OFF | DCV/OFF-ON |
| EFTA | PID | 50-120 (K) | 50-120 (K) | 50-120 (K) | 50-120 (K) | DEG |
| FLI (H) | PID | 50 | 50 | 50 | 50 | % |
| LOAD | PID | (L) | 10-20 | 16-30 | 20-30 | % |
| MISF | PID | OFF | OFF | OFF | OFF | OFF-ON |
| OCTADJS | PID | NO RETARD | NO RETARD | NO RETARD | NO RETARD | NO RETARD/RETARD |
| RPM | PID | 0 | 630-750 | 1180-1360 | 1530-1750 | RPM |
| VSS | PID | 0 | 0 | 30 | 55 | MPH |
ACTUATORS/OUTPUTS - 4.6L 4V MUSTANG SVT COBRA SUPERCHARGED
| Actuators/Outputs | PCM Pin/PID only | Measured/PID Values | Units Measured/PID | |||
|---|---|---|---|---|---|---|
| KOEO | Hot Idle | 30 MPH | 55 MPH | |||
| CDE (CYL6) | 1 | VBAT | VBAT | VBAT | VBAT | DCV |
| CDA (CYL1) | 26 | VBAT | VBAT | VBAT | VBAT | DCV |
| CDF (CYL5) | 27 | VBAT | VBAT | VBAT | VBAT | DCV |
| LFC | 28 | .1/OFF | VBAT/ON (B) | .1/OFF | .1/OFF | DCV/OFF-ON |
| HFC | 46 | VBAT/OFF | .1/ON (B) | VBAT/OFF | VBAT/OFF | DCV/OFF-ON |
| SCB | 45 | .1/ON | VBAT/OFF | VBAT/OFF | VBAT/OFF | DCV/OFF-ON |
| EGRVR | 47 | VBAT/0 | VBAT/0 | (V) | (V) | DCV/% |
| CDB (CYL3) | 52 | VBAT | VBAT | VBAT | VBAT | DCV |
| CDG (CYL4) | 53 | VBAT | VBAT | VBAT | VBAT | DCV |
| EVAPPDC | 56 | 0 | 0-10/0-100 | 0-10/0-100 | 0-10/0-100 | Hz/% |
| EVAPCV | 67 | VBAT/0 | VBAT/0 | VBAT/0 (S) | VBAT/0 (S) | DCV/% |
| VSO | 68 | 0 | 0 | 65 | 125 | Hz |
| WAC | 69 | .1/ON | VBAT/OFF (A) | .1/ON | .1/ON | DCV/OFF-ON |
| INJ7 | 72 | 0 | 2.4-2.8 | 1.6-5 | 3.3-6 | mS |
| INJ5 | 73 | 0 | 2.4-2.8 | 1.6-5 | 3.3-6 | mS |
| INJ3 | 74 | 0 | 2.4-2.8 | 1.6-5 | 3.3-6 | mS |
| INJ1 | 75 | 0 | 2.4-2.8 | 1.6-5 | 3.3-6 | mS |
| CDC (CYL7) | 78 | VBAT | VBAT | VBAT | VBAT | DCV |
| CDH (CYL8) | 79 | VBAT | VBAT | VBAT | VBAT | DCV |
| FP | 80 | 3.6/75 | 1.2/24 | 1.2/24 | 1.2/24 | DCV/% |
| SBICP | 82 | VBAT/OFF | .1/ON | .1/ON | .1/ON | DCV/OFF-ON |
| IAC | 83 | VBAT/0 | 10.3/35 | 8.7-9/34-46 (L) | 8-9/34-54 (L) | DCV/% |
| HTR11 | 93 | .1/ON (P) | .1/ON | .1/ON | .1/ON | DCV/OFF-ON |
| HTR21 | 94 | .1/ON (P) | .1/ON | .1/ON | .1/ON | DCV/OFF-ON |
| HTR12 | 95 | .2/ON (P) | .2/ON | .2/ON | .2/ON | DCV/OFF-ON |
| HTR22 | 96 | .2/ON (P) | .2/ON | .2/ON | .2/ON | DCV/OFF-ON |
| INJ8 | 98 | 0 | 2.4-2.8 | 1.6-5 | 3.3-6 | mS |
| INJ6 | 99 | 0 | 2.4-2.8 | 1.6-5 | 3.3-6 | mS |
| INJ4 | 100 | 0 | 2.4-2.8 | 1.6-5 | 3.3-6 | mS |
| INJ2 | 101 | 0 | 2.4-2.8 | 1.6-5 | 3.3-6 | mS |
| CDD (CYL2) | 104 | VBAT | VBAT | VBAT | VBAT | DCV |
| FUELPW1 | PID | (L) | 2.4-2.8 | 1.6-5 | 3.3-6 | mS |
| FUELPW2 | PID | (L) | 2.4-2.8 | 1.6-5 | 3.3-6 | mS |
| LONGFT1 | PID | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | % |
| LONGFT2 | PID | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | % |
| MIL | PID | OFF | OFF | OFF | OFF | OFF-ON |
| SHRTFT1 | PID | (L) | (-)10-(+)10 | (-)10-(+)10 | (-)10-(+)10 | % |
| SHRTFT2 | PID | (L) | (-)10-(+)10 | (-)10-(+)10 | (-)10-(+)10 | % |
| SPARKADV | PID | 0 | 11-15 | 17-32 | 19-34 | DEG |
OTHERS - 4.6L 4V MUSTANG SVT COBRA SUPERCHARGED
| Other | PCM Pin/PID only | Measured/PID Values | Units Measured/PID | |||
|---|---|---|---|---|---|---|
| KOEO | Hot Idle | 30 MPH | 55 MPH | |||
| KAPWR | 55 | VBAT | VBAT | VBAT | VBAT | DCV |
| VPWR | 71 | VBAT | VBAT | VBAT | VBAT | DCV |
| VREF | 90 | 5 | 5 | 5 | 5 | DCV |
GENERIC OBD II PID VALUES - 4.6L 4V MUSTANG SVT COBRA SUPERCHARGED
|
NOTE:
All generic OBD II readings under no load (PARK or NEUTRAL).
|
|||
|---|---|---|---|
| PID | Hot Idle | 2500 RPM | Units |
| LONGFT1 | (-)20-(+)20 | (-)20-(+)20 | % |
| LONGFT2 | (-)20-(+)20 | (-)20-(+)20 | % |
| LOAD | 23-35 | 17-23 | % |
| MAF | 4.3-5.3 | 15-18 | G/S |
| SHRTFT1 | (-)10-(+)10 | (-)10-(+)10 | % |
| SHRTFT2 | (-)10-(+)10 | (-)10-(+)10 | % |
| SHRTFT11 | (-)10-(+)10 | (-)10-(+)10 | % |
| SHRTFT12 | 95-100 | 95-100 | % |
| SHRTFT21 | (-)10-(+)10 | (-)10-(+)10 | % |
| SHRTFT22 | 95-100 | 95-100 | % |
| SPARKADV | 11-15 | 30 | DEG |