LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.0 3, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 2776 (Engine Controls - Reference Values - F-150 Through Focus - CNG, Flex-Fuel & Gasoline) >> F-250/F-350-Series 5.4L (4R100)

F-250/F-350-Series 5.4L (4R100)

WARNING: This page does not describe the selected car, but rather 30 other vehicles, including the 2004 Mercury Sable, 2004 Mercury Mountaineer, 2004 Mercury Monterey, 2004 Mercury Marauder, and 2004 Mercury Grand Marquis. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying 104 Pin PCM Connector - 5.4L F-250/F-350-Series (4R100)
G03626777Courtesy of FORD MOTOR CO.
SENSORS/INPUT - 5.4L F-250/F-350-SERIES (4R100)

Sensors/Inputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 30 MPH 55 MPH
PTO 4 .1/OFF  .1/OFF  .1/OFF  .1/OFF  DCV/OFF-ON
FEPS 13 .5-.6  .5-.6  .5-.6  .5-.6  DCV
CKP (+) 21 360-380  700-800  900-1100  Hz
TCS 29 .1/OFF  VBAT/ON(G)  .1/OFF  .1/OFF  DCV/OFF-ON
TR1 34 11.5  11.5  DCV
O2S12 (M) 35 (D)  (D)  (D)  DCV
TFT 37 .5-2/210-110  .5-2/210-110  .5-2/210-110  .5-2/210-110  DCV/DEG
IAT 39 1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  DCV/DEG
FPM 40 .1/OFF  VBAT/ON  VBAT/ON  VBAT/ON  DCV/OFF-ON
ACCS 41 .1/OFF  VBAT/ON (A)  .1/OFF  .1/OFF  DCV/OFF-ON
TR2 49 11.5  11.5  DCV
TR4 50 11.5  11.5  DCV
KS 57 DCV
VSS 58 65/30  125/55  Hz/MPH
TSS 59 325/610  740/925  0/1660  Hz/RPM
O2S11 60 switching (C)  switching (C)  switching (C)  DCV
FTP V/FTP (M) 62 2.6/0  2.6/0  2.6/0  2.6/0  DCV/IN-H2O
TR V/TR 64 0/PARK  0/PARK  1.7/OD  1.7/OD  DCV/MODE
DPFEGR 65 .25-1.3  .25-1.3  .25-4.65  .25-4.65  DCV
CHT V/CHT 66 .6 or 3.7/194  .6 or 3.7/194  .6 or 3.7/194  .6 or 3.7/194  DCV/DEG
OSS 84 130/1320  240/2385  Hz/RPM
CID 85 5-8  10-12  14-17  Hz
O2S21 87 switching (C)  switching (C)  switching (C)  DCV
MAF V 88 .7-.9  1-1.6  1.7-2.4  DCV
TP V 89 .53-1.27  .53-1.27  .8-1.2  .9-1.6  DCV
BPP 92 .1/OFF  VBAT/ON (E)  .1/OFF  .1/OFF  DCV/OFF-ON
4X4L (M) PID OFF  OFF  OFF  OFF  OFF-ON
CPP/PNP PID ON  ON  OFF  OFF  OFF-ON
FLI (H) PID 50  50  50  50  %
GEAR PID GEAR
LOAD PID 15-20  21-30  30-45  %
MISF PID OFF  OFF  OFF  OFF  OFF-ON
OCTADJS PID NO RETARD  NO RETARD  NO RETARD  NO RETARD  NO RETARD/RETARD
RPM PID 630-700  1100-1200  1150-1400  RPM
VSS PID 30  55  MPH
ACTUATORS/OUTPUTS - 5.4L F-250/F-350-SERIES (4R100)

Actuators/Outputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 30 MPH 55 MPH
CDE (CYL6) 1 VBAT  VBAT  VBAT  VBAT  DCV
SS1 6 .1/ON  .1/ON  .1/ON  .1/ON  DCV/OFF-ON
SS2 11 VBAT/OFF  VBAT/OFF  .1/ON  .1/ON  DCV/OFF-ON
TCIL 12 VBAT/OFF  VBAT/OFF  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
CCS 20 .1/OFF  .1/OFF  .1/OFF  .1/OFF  DCV/OFF-ON
CDA (CYL1) 26 VBAT  VBAT  VBAT  VBAT  DCV
CDF (CYL5) 27 VBAT  VBAT  VBAT  VBAT  DCV
EGRVR (M) 47 VBAT/0  VBAT/0  (V)  (V)  DCV/%
CTO (M) 48 41-44  80-90  113  Hz
CDB (CYL3) 52 VBAT  VBAT  VBAT  VBAT  DCV
CDG (CYL4) 53 VBAT  VBAT  VBAT  VBAT  DCV
TCC 54 .2/100  VBAT/0  VBAT/0  .2/100  DCV/%
EVAPPDC 56 0-10/0-100  0-10/0-100  0-10/0-100  Hz/%
EVAPCV (M) 67 VBAT/0  VBAT/0  VBAT/0 (S)  VBAT/0 (S)  DCV/%
WAC 69 .1/OFF  VBAT/ON (A)  .1/OFF  .1/OFF  DCV/OFF-ON
INJ7 72 3.2-4.2  4-8  8-16  mS
INJ5 73 3.2-4.2  4-8  8-16  mS
INJ3 74 3.2-4.2  4-8  8-16  mS
INJ1 75 3.2-4.2  4-8  8-16  mS
CDC (CYL7) 78 VBAT  VBAT  VBAT  VBAT  DCV
CDH (CYL8) 79 VBAT  VBAT  VBAT  VBAT  DCV
FP 80 VBAT/0  .1/100  .1/100  .1/100  DCV/%
EPC 81 8/0  9.5/0  10.5/40  10.5/40  DCV/PSI
IAC 83 VBAT/0  11.7/25  8.5-10.9/30-55 (L)  6-8/50-70 (L)  DCV/%
HTR11 93 .1/ON (P)  .1/ON  .1/ON  .1/ON  DCV/OFF-ON
HTR21 94 .1/ON (P)  .1/ON  .1/ON  .1/ON  DCV/OFF-ON
HTR12 (M) 95 .2/ON (P)  .2/ON  .2/ON  .2/ON  DCV/OFF-ON
INJ8 98 3.2-4.2  4-8  8-16  mS
INJ6 99 3.2-4.2  4-8  8-16  mS
INJ4 100 3.2-4.2  4-8  8-16  mS
INJ2 101 3.2-4.2  4-8  8-16  mS
CDD (CYL2) 104 VBAT  VBAT  VBAT  VBAT  DCV
CHTIL PID OFF  OFF  OFF  OFF  OFF-ON
FUELPW1 PID (L)  3.2-4.2  4-8  8-16  mS
FUELPW2 PID (L)  3.2-4.2  4-8  8-16  mS
LONGFT1 PID (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  %
LONGFT2 PID (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  %
MIL PID OFF  OFF  OFF  OFF  OFF-ON
SHRTFT1 PID (L)  (-)10-(+)10  (-)10-(+)10  (-)10-(+)10  %
SHRTFT2 PID (L)  (-)10-(+)10  (-)10-(+)10  (-)10-(+)10  %
SPARKADV PID 20-25  25-32  20-37  DEG
OTHERS - 5.4L F-250/F-350-SERIES (4R100)

Other PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 30 MPH 55 MPH
KAPWR 55 VBAT  VBAT  VBAT  VBAT  DCV
VPWR 71 VBAT  VBAT  VBAT  VBAT  DCV
VREF 90 DCV
GENERIC OBD II PID VALUES - 5.4L F-250/F-350-SERIES (4R100)

NOTE: All generic OBD II readings under no load (PARK or NEUTRAL).
PID Hot Idle 2500 RPM Units
LONGFT1 (-)20-(+)20  (-)20-(+)20  %
LONGFT2 (-)20-(+)20  (-)20-(+)20  %
LOAD 15-20  20-25  %
MAF 4.8-6  18.1-21  G/S
SHRTFT1 (-)10-(+)10  (-)10-(+)10  %
SHRTFT2 (-)10-(+)10  (-)10-(+)10  %
SHRTFT11 (-)10-(+)10  (-)10-(+)10  %
SHRTFT12 95-100  95-100  %
SHRTFT21 (-)10-(+)10  (-)10-(+)10  %
SPARKADV 20-25  42  DEG