  1. Remove the RH ignition coil-on-plugs. For additional information, refer to IGNITION COIL-ON-PLUG .
  2. Detach the 3 main engine control wiring harness retainers from the valve cover stud bolts.
  3. Detach the 3 main engine control wiring harness retainers from the valve cover.
  4. Disconnect the Variable Camshaft Timing (VCT) electrical connector.
  5. Detach the Crankshaft Position (CKP) wiring harness retainer from the stud.
  6. Remove the 11 bolts, 3 stud bolts and the valve cover.
    • Remove and discard the gasket.