Valve Cover - LH: Removal

WARNING: This page is about a different car, the 2010 Mercury Mariner and 2010 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: During engine repair procedures, cleanliness is extremely important. Any foreign material (including any material created while cleaning gasket surfaces) that enters the oil passages, coolant passages or the oil pan may cause engine failure.
  1. Remove the LH ignition coil-on-plugs. For additional information, refer to IGNITION COIL-ON-PLUG .
  2. Detach the upper radiator hose from the 2 retainers on the cooling fan shroud and position the hose aside.
  3. Detach the 2 wiring retainers from the valve cover.
  4. Detach the 2 wiring retainers from the valve cover stud bolts.
  5. Disconnect the Variable Camshaft Timing (VCT) electrical connector.
  6. Disconnect the Heated Oxygen Sensor (HO2S) electrical connector.
  7. NOTE: Inspect the crankcase ventilation tube and valve cover sealing area. If either a new valve cover or crankcase ventilation tube is required, both components must be installed new.
  8. Remove the 8 bolts, 6 stud bolts and the valve cover.
    • Remove and discard the gasket.