Test F: Warning Indicator Flickers Or Operates Intermittently
WARNING: This page is about a different car, the 2004 Ford Ranger. However, it is still accessible from the selected car via links, so may be relevant.
- Check For Loose Connections
Inspect all generator, power distribution and battery connections for looseness, corrosion, and loose or bent terminals. Are all connections clean and tight? If yes, go to next step. If no, repair as necessary. Test system for normal operation. - Check Fuse Connections
Start engine and let idle. Check smart junction box fuse No. 10 (10-amp) for looseness. Wiggling fuse and note warning indicator operation. Does the charging system warning indicator flicker? If yes, repair loose connection as necessary. Test system for normal operation. If no, go to next step. - Check "A" Circuit (Yellow/White Wire) Connections
Turn ignition off. Using a fused jumper wire (30-amp) connected to positive battery terminal, backprobe generator harness connector terminal No. 3 (Yellow/White wire). See Figure or Figure . Start engine and let idle. Note warning indicator operation. Does the charging system warning indicator flicker? If yes, for 2.3L engine, install a new generator. See GENERATOR under REMOVAL & INSTALLATION. Test the system for normal operation. For 3.0L engine or 4.0L engine, go to next step. If no, repair loose connection(s) in the circuits. Test the system for normal operation. - Inspect "S" Terminal
Turn ignition off. Check generator 1-pin harness connector for damage, corrosion and looseness (White/Black wire). See Figure. Is the "S" terminal in satisfactory condition? If yes, go to next step. If problem exists, repair as necessary. Test system for normal operation. - Check Generator Brushes
Remove generator from vehicle. See GENERATOR under REMOVAL & INSTALLATION. Measure resistance between voltage regulator "F" terminal screw on back of generator and generator 3-pin connector terminal No. 3, component side. See Figure and Fig 1 . Is the resistance less than 5 ohms? If yes, replace generator. If no, go to next step. - Check For A Grounded Slip Ring
Remove voltage regulator and brush holder. See VOLTAGE REGULATOR under REMOVAL & INSTALLATION. Measure resistance between generator housing and each generator slip ring. See Fig 2. Is the resistance greater than 10,000 ohms? If yes, replace voltage regulator. If no, replace generator. See GENERATOR under REMOVAL & INSTALLATION.