Normal Operation
The LH front power window control switch receives power from the delayed accessory relay through circuit CPB02 (GN) and is grounded through circuit GD126 (BK/WH). When the LH front window control switch is pressed to the UP position, the LH front motor receives power through circuit CPW11 (BU/GY). When the LH front window control switch is pressed to the DOWN position, the LH front motor receives power through circuit CPW10 (YE/VT). When the LF window motor receives a ground signal on circuit CPW29 (VT/GY), the LF window motor will enter one-touch up or one-touch down.
The RH front power window control switch receives power from the delayed accessory relay through circuit CPB02 (GN) and is grounded through circuit GD126 (BK/WH). When the RH front window control switch is pressed to the UP position, the RH front motor receives power through circuit CPW13 (BN/YE). When the RH front window control switch is pressed to the DOWN position, the RH front motor receives power through circuit CPW12 (GN/OG). When the RH window motor receives a ground signal on circuit CPW31 (GN/WH), the RH window motor will enter one-touch up or one-touch down.