LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.0 3, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1387 (Instrument Cluster System) >> Diagnosis And Testing >> Instrument Cluster >> Pinpoint Tests >> Pinpoint Test AB: The Instrument Cluster Is Inoperative >> Pinpoint Test Ab: The Instrument Cluster Is Inoperative

Pinpoint Test Ab: The Instrument Cluster Is Inoperative

WARNING: This page is about a different car, the 2006 Mercury Grand Marquis and 2006 Ford Crown Victoria. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION: Use the correct probe adaptor(s) when making measurements. Failure to use the correct probe adaptor(s) may damage the connector.
  1. AB1 CHECK THE INSTRUMENT CLUSTER VOLTAGE SUPPLY 
    • Key in OFF position.
    • Disconnect: Instrument Cluster C2220.
    • Key in ON position.
    • Measure the voltage between the instrument cluster, harness side and ground as follows:
      SPECIAL TOOL DESCRIPTION

      Instrument Cluster Connector-Pin Circuit
      C2220-1 54 (LG/YE)
      C2220-17 1003 (GY/YE)
      C2220-19 640 (RD/YE)
    • Are the voltages greater than 10 volts? 

    Yes  : GO to AB2.

    No  : VERIFY the CJB fuses 1 (15A), 6 (10A) and 26 (10A) are OK. If OK, REPAIR the circuit in question. TEST the system for normal operation.

  2. AB2 CHECK INSTRUMENT CLUSTER GROUND CIRCUITS 
    • Key in OFF position.
    • Measure the resistance between the instrument cluster, harness side and ground as follows:
      CONNECTOR TERMINALS RESISTANCE DESCRIPTION

      Instrument Cluster Connector-Pin Circuit
      C2220-2 676 (PK/OG)
      C2220-18 57 (BK)
    • Are the resistances less than 5 ohms? 

    Yes  : GO to AB3.

    No  : REPAIR the circuit in question. TEST the system for normal operation.

  3. AB3 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION 
    • Disconnect the instrument cluster connector.
    • Check for:
      • corrosion
      • pushed-out pins
    • Connect the instrument cluster connector and make sure it seats correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 

    Yes  : INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER . TEST the system for normal operation.

    No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.