LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.0 3, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1108 (Exterior Lighting System) >> Diagnosis And Testing >> Autolamps >> Pinpoint Tests >> Pinpoint Test G: The Autolamps Are Inoperative >> Testing

Pinpoint Test G: The Autolamps Are Inoperative: Testing

WARNING: This page is about a different car, the 2005 Mercury Montego, 2005 Ford Freestyle, and 2005 Ford Five Hundred. However, it is still accessible from the selected car via links, so may be relevant.
  1. G1 CHECK SMART JUNCTION BOX (SJB) DTCs 
    • Key in OFF position.
    • Using the recorded results from the SJB self-test:
    • Was DTC B1793 recorded? 
    • Yes  : GO to  G3.
    • No  : GO to G2.
  2. G2 CHECK THE MANUAL HEADLAMP AND PARKING LAMP OPERATION 
    • Place the headlamp switch in the HEADLAMPS ON position.
    • Do the headlamps and parking lamps operate correctly? 
  3. G3 CHECK FOR VOLTAGE TO THE LIGHT SENSOR 
    • Disconnect: Light Sensor C286.
    • Key in ON position.
    • Place the headlamp switch in the AUTOLAMPS ON position.
    • Measure the voltage between the light sensor C286-2, circuit 1416 (YE/WH), harness side and ground.
    • Fig 1: Checking For Voltage To Light Sensor
      G03992770Courtesy of FORD MOTOR CO.
    • Is the voltage approximately 5 volts? 
    • Yes  : INSTALL a new light sensor. CLEAR the DTCs. REPEAT the self-test.
    • No  : GO to G4.
  4. G4 CHECK CIRCUIT 1416 (YE/WH) FOR A SHORT TO GROUND 
    • Key in OFF position.
    • Disconnect: SJB C2280d.
    • Measure the resistance between the light sensor C286-2, circuit 1416 (YE/WH), harness side and ground.
      Fig 2: Checking Circuit 1416 (YE/WH) For Short To Ground
      G03992767Courtesy of FORD MOTOR CO.
    • Is the resistance greater than 10,000 ohms? 
    • Yes  : GO to G5.
    • No  : REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test.
  5. G5 CHECK FOR CORRECT SJB OPERATION 
    • Disconnect all the SJB connectors.
    • Check for:
      • corrosion
      • pushed-out pins
    • Connect all the SJB connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test.