LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.0 3, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1003 (Instrument Cluster System -- F150 Pickup) >> Diagnosis And Testing >> Instrument Cluster >> Pinpoint Test S: The Electronic Throttle Control (ETC) Warning Indicator Is Never/Always On >> Pinpoint Test S: The Electronic Throttle Control (Etc) Indicator Is Never/Always On

Pinpoint Test S: The Electronic Throttle Control (Etc) Indicator Is Never/Always On

WARNING: This page is about a different car, the 2005 Ford Pickup. However, it is still accessible from the selected car via links, so may be relevant.
  1. S1 RETRIEVE THE RECORDED POWERTRAIN CONTROL MODULE (PCM) DTCs FROM BOTH THE CONTINUOUS AND ON-DEMAND SELF-TESTS 
    • Check for the recorded PCM DTCs from the continuous and on-demand self-tests.
    • Are any PCM DTCs recorded? 
  2. S2 CARRY OUT THE INSTRUMENT CLUSTER WARNING LAMPS AND CHIME ACTIVE COMMAND USING THE DIAGNOSTIC TOOL 
    • Key in ON position.
    • Enter the following diagnostic mode on the diagnostic tool: Instrument Cluster Active Command.
    • Select the instrument cluster warning lamps and chime active command. Trigger the all warning lamps active command on and off. Observe the ETC warning indicator.
    • Does the ETC warning indicator turn on when triggered on and turn off when triggered off? 
    • Yes  : GO to  S3.
    • No  : GO to  S4.
  3. S3 CHECK FOR CORRECT PCM OPERATION 
    • Disconnect all the PCM connectors.
    • Check for:
      • Corrosion
      • Pushed-out pins
    • Connect all the PCM connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new PCM. REFER to ELECTRONIC ENGINE CONTROLS . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
  4. S4 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION 
    • Disconnect all the instrument cluster connectors.
    • Check for:
      • Corrosion
      • Pushed-out pins
    • Connect all the instrument cluster connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.