Charge Warning Never On
- Turn ignition on. If charge warning indicator illuminates, see appropriate GENERATOR or STARTER article in the ELECTRICAL section. If charge warning indicator does not illuminate, go to next step.
- Turn ignition off. Disconnect generator 3-pin connector. Turn ignition on. Connect a jumper wire between ground and generator 3-pin connector (Green/Black wire). If charge warning indicator illuminates, see appropriate GENERATOR or STARTER article in the ELECTRICAL section. If charge warning indicator does not illuminate, go to next step.
- Turn ignition off. Remove instrument cluster. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. Disconnect instrument cluster connector C1. See Figure and Figure . Measure resistance of Green/Black wire between generator 3-pin connector and instrument cluster connector C1 terminal No. 7. If resistance is less than 5 ohms, inspect charge warning indicator bulb and replace as necessary. If bulb is okay, replace instrument cluster printed circuit. See PRINTED CIRCUIT under REMOVAL & INSTALLATION. If resistance is more than 5 ohms, repair open Green/Black wire.