Knock Sensor
WARNING: This page is about a different car, the 1995 Mazda Millenia. However, it is still accessible from the selected car via links, so may be relevant.
Disconnect knock sensor connector. Measure resistance between knock sensor terminals. Resistance should be approximately 560,000 ohms at 68°F (20°C). Replace sensor if resistance is not as specified.