Pinpoint Test Ac - Low Oil Warning Never/Always On
- Check fuses and inspect connectors for looseness or damage. Inspect wiring for looseness or damage. If a problem is found, repair as necessary and then proceed to step 3). If fuses, connections and wiring are okay, go to next step.
- Connect scan tool to Data Link Connector (DLC) and retrieve continuous codes. Perform on demand self test. If DTC B1384 is retrieved as a self test and continuous code, go to step 4). If DTC B1383 is retrieved as a self test and continuous code, Repair battery short in White/Pink wire between Generic Electronic Module (GEM) and oil level warning lamp.
- Connect scan tool to Data Link Connector (DLC) and run wiggle test. If no DTC sets, malfunction is not present at this time. If DTC B1391 is set Check Whit/Pink wire for short to ground in White/Pink wire between Generic Electronic Module (GEM) and oil level warning lamp. Repair as necessary. If okay, go to step 5).
- Check LOW OIL bulb for continuity. Replace as necessary. If bulb is okay, go to next step.
- Disconnect oil level sensor and ground White/Pink wire. On scan tool, read PID OIL-LVL. If display reads 0.0%, go to next step. If display does not read 0.0%, repair open in White/Pink wire, and return to step 2).
- Check for open sensor ground (Gray wire) between ground and oil level sensor. Repair Gray wire as necessary. If wire is okay, replace oil level sensor.