Pinpoint Test L - Battery VLTGE Gauge Inoperative/Inaccurate
- Ensure charging system is okay. Turn ignition off. Remove instrument cluster. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION.
- Turn ignition off. Measure resistance between instrument cluster circuit board pin 1F and "+" screw on voltmeter. If resistance is less than 5 ohms, go to next step. If resistance is not less than 5 ohms, replace instrument cluster printed circuit board.
- Measure resistance between instrument cluster circuit board pin 1I and "-" terminal on voltmeter. If resistance is less than 5 ohms, replace voltmeter. If resistance is not less than 5 ohms, replace instrument cluster printed circuit board.