Special Test Mode
NOTE:
Before performing PINPOINT TESTS, check instrument cluster using SPECIAL TEST MODE.
- Press E/M and SELECT buttons simultaneously while turning ignition on. Cluster will enter SPECIAL TEST MODE and display information in center display opening. Display includes 2 numbers in odometer and a number in speedometer.
- If display in center opening flashes continuously, replace cluster. If display does not flash, turn ignition off to exit SPECIAL TEST MODE. Continue with appropriate PINPOINT TEST since cluster may or may not be faulty.