Cs Displayed, Gauge Blanks Out Fuel Tank Symbol & Displays Top 2 & Bottom 2 Bars Of Gauge
- Disconnect battery ground cable. Remove cluster. Secure connectors to prevent shorting. Measure resistance between cluster connector "A" terminals No. 6 (Yellow/White wire) and 8 (Orange/Yellow wire). See Figure . If resistance is 11-168 ohms, replace cluster. If resistance is not as specified, a short circuit exists in harness or sender.
- Disconnect battery ground cable. Lower fuel tank to access fuel sender connector. Unplug fuel sender connector. Measure resistance between cluster connector "A" terminals No. 6 (Yellow/White wire) and 8 (Orange/Yellow wire). If resistance is greater than 10,000 ohms, replace sender. If resistance is not as specified, check fuel sender wiring for a short circuit.