Air Pressure Tests: Governor
- In order to check lines to governor passage and governor to valve body passage, drive shaft crossmember and extension housing must be removed. Apply air pressure to governor passage while holding finger near governor valve. Air should be felt exiting valve.
- To air pressure check governor to valve body passage, governor must be removed. Apply air pressure to passage while holding finger over holes in output shaft. Air should be felt exiting one of the holes.