Pressure Bleeding: Non-ABS
- Release all vacuum from power unit by depressing brake pedal several times. Clean dirt from brake fluid reservoir cap and surrounding area, then remove cap. With pressure tank at least1/2 full of brake fluid and charged with 10-30 psi (.70-2.10 kg/cm2 ) air pressure, connect tank to master cylinder using proper adapter(s).
- Attach bleeder hose to first bleeder valve to be serviced. See BRAKELINE BLEEDING SEQUENCE . Place other end of hose in clean transparent container. Partially fill container with clean brake fluid until end of hose is submerged in fluid.
- Open release valve on pressure bleeder. Open bleeder valve 1-2 turns, noting fluid flow. When fluid flowing into container is clear and free of bubbles, close bleeder valve securely.
- Finish bleeding system in same manner using correct sequence. Remove pressure tank from master cylinder and check fluid level of master cylinder reservoir.