Fuel Sender/Pump Unit
- Connect ohmmeter lead to ground terminal or housing, and other lead to resistance terminal. With float at EMPTY position, ohmmeter should be 75 ohms (22.5 ohms on magnetic-type gauge).
- With float at FULL position, resistance should be 10 ohms (145 ohms on magnetic-type gauge). Resistance change should be smooth as float is moved. If readings are incorrect or resistance change readings jump erratically, replace sender/pump unit.