Oil Pressure Gauge Bench Test
To test gauge for open windings, remove gauge from cluster. Connect gauge to ohmmeter and read resistance. A reading of 10-14 ohms is normal because current increases temperature of gauge coil windings. If ohmmeter reads below 10 ohms or above 14 ohms, replace gauge.