Home >> Fiat >> 2021 >> 500X Trekking >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating & Air Conditioning - DTCS B1912-15 To U2031-87 >> DTC Troubleshooting >> B1931-11-PTC Low Power Relay Driving Command Output - Circuit Short To Ground >> Diagnostic Test

Diagnostic Test

  1. CHECK FOR AN ACTIVE DTC 
    1. With the scan tool, read DTCs and record on the repair order.
    2. Record the Environmental Data.
    3. With the scan tool, erase DTCs.
    4. Using the recorded Environmental Data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
    5. With the scan tool, read HVAC Module DTCs.

      Did the DTC return?

      Yes 

      • Go To  2

      No 

  2. REPLACE THE POSITIVE TEMPERATURE COEFFICIENT (PTC) 1 RELAY WITH A KNOWN GOOD RELAY AND CHECK FOR THE DTC TO RETURN 
    1. Replace the PTC 1 Relay in accordance with the Service Information.
    2. Turn the ignition on.
    3. With the scan tool, erase DTCs.
    4. Using the Environmental Data and When Monitored conditions, operate the vehicle within the conditions that set the DTC.
    5. With the scan tool, read DTCs.

      Did the DTC return?

      Yes 

      • Go To  3

      No 

      • Replacing the PTC 1 Relay corrected the condition.
      • Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
  3. CHECK THE (C361) CABIN HEATER 1 RELAY CONTROL CIRCUIT FOR A SHORT TO GROUND 
    1. Turn the ignition off.
    2. Disconnect the HVAC Module harness connector.
    3. Remove the PTC 1 Relay from the Power Distribution Center.
    4. Turn the ignition on.
    5. Check for continuity between ground and the (C361) Cabin Heater 1 Relay Control circuit.

      Is there continuity between ground and the (C361) Cabin Heater 1 Relay Control circuit?

      Yes 

      • Repair the (C361) Cabin Heater 1 Relay Control circuit for a short to ground.
      • Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .

      No 

      • Go To  4
  4. CHECK RELATED HARNESS CONNECTIONS 
    1. Disconnect all HVAC Module harness connectors.
    2. Disconnect all related in-line harness connections (if equipped).
    3. Disconnect the related component harness connectors.
    4. Inspect harness connectors, component connectors, and all male and female terminals for the following conditions:
      • Proper connector installation.
      • Damaged connector locks.
      • Corrosion.
      • Other signs of water intrusion.
      • Weather seal damage (if equipped).
      • Bent terminals.
      • Overheating due to a poor connection (terminal may be discolored due to excessive current draw).
      • Terminals that have been pushed back into the connector cavity.
      • Perform a terminal drag test on each connector terminal to verify proper terminal tension.

      Repair any conditions that are found.

    5. Reconnect all HVAC Module harness connectors. Be certain that all harness connectors are fully seated and the connector locks are fully engaged.
    6. Reconnect all in-line harness connectors (if equipped). Be certain that all connectors are fully seated and the connector locks are fully engaged.
    7. Reconnect all related component harness connectors. Be certain that all connectors are fully seated and the connector locks are fully engaged.
    8. With the scan tool, erase DTCs.
    9. Using the recorded Environmental Data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
    10. With the scan tool, read HVAC Module DTCs.

      Did the DTC return?

      Yes 

      No 

      • The wiring or poor connection problem has been repaired.
      • Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .