When Monitored And Set Conditions
When Monitored: continuously when the following condition is met:
- Ignition on.
Set Conditions:
- The HVAC Module detects a short to ground or an open in the Left Blend Door Driver 1 or Driver 2 circuit.
Default Actions:
- If the HVAC Module detects a valid current draw, the DTC will change from Active to Stored and will stay in the controllers memory for 100 ignition cycles.
| Possible Causes |
|---|
| LEFT BLEND DOOR DRIVER 1 CIRCUIT SHORTED TO GROUND |
| LEFT BLEND DOOR DRIVER 2 CIRCUIT SHORTED TO GROUND |
| LEFT BLEND DOOR DRIVER 1 CIRCUIT OPEN |
| LEFT BLEND DOOR DRIVER 2 CIRCUIT OPEN |
| LEFT BLEND DOOR ACTUATOR |
| HVAC MODULE |
Always perform the PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE before proceeding. Refer to PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE .