Valve, Surge: Installation

WARNING: This page is about a different variant/trim than selected.
  1. Install the surge vale into the turbocharger housing.
  2. Install the three bolts (1). Tighten the bolts and the nuts to 9 N.m (80 in. lbs.)
  3. Connect the surge valve connector (2).
    GC0153792Courtesy of CHRYSLER GROUP, LLC
  4. Install the upper heat sheild.
  5. Install the new nuts (2) and the three bolts (1). Tighten to 9 N.m (80 in. lbs.)
    GC0153787Courtesy of CHRYSLER GROUP, LLC
  6. Install the air cleaner assembly (1)
  7. Connect the two vacuum fittings (4), tighten the clamp (3) at the air to turbocharger inlet tube.
  8. Connect the fresh air intake hose (2).