Set Condition
The Occupant Restraint Controller (ORC) monitors the voltage on the Left Seat Airbag circuits. If voltage is detected on the Left Seat Airbag circuits for greater than 2.6 seconds the ORC will set this DTC. The DTC will change from Active to Stored status when the fault condition is not detected for greater than 2.6 seconds. The multifunction indicator lamp (MIL) will set in the instrument cluster.