Fig 1: Liquid Line Fitting O-Ring
GC0152397Courtesy of CHRYSLER GROUP, LLC
  1. Lubricate a new rubber O-ring seal (1) with clean refrigerant oil and install it onto the A/C liquid line fitting (2).
    Fig 2: Liquid Line, A/C Pressure Transducer & Connector
    GC0152396Courtesy of CHRYSLER GROUP, LLC
  2. Install the A/C pressure transducer (2) onto the A/C liquid line (3). Tighten the A/C pressure transducer to 5.1 N.m (45 in. lbs.).
  3. Connect the wire harness connector (1) to the A/C pressure transducer.