Module, Convergence Telematics: Installation: Installation

WARNING: This page is about a different car, the 2015 Fiat 500. However, it is still accessible from the selected car via links, so may be relevant.
WARNING:

To avoid serious or fatal injury on vehicles equipped with airbags, disable the Supplemental Restraint System (SRS) before attempting any steering wheel, steering column, airbag, seat belt tensioner, impact sensor or instrument panel component diagnosis or service. Disconnect and isolate the battery negative (ground) cable, then wait two minutes for the system capacitor to discharge before performing further diagnosis or service. This is the only sure way to disable the SRS. Failure to take the proper precautions could result in accidental airbag deployment.

Fig 1: Harness Clip, CTM Bracket & CTM
GC0153051Courtesy of CHRYSLER GROUP, LLC
  1. Position the Convergence Telematics Module (CTM) (3) into the vehicle through the instrument panel glove box module opening.
  2. Engage the instrument panel wire harness retainer (1) onto the CTM mounting bracket (2).
    Fig 2: Harness Connector
    GC0153050Courtesy of CHRYSLER GROUP, LLC
  3. Reconnect the instrument panel wire harness connectors (1) to the CTM connector receptacles.
    Fig 3: Convergence Telematic Module (CTM) & Bracket Mounting Retainer
    GC0153049Courtesy of CHRYSLER GROUP, LLC
  4. Position the CTM (1) mounting bracket to the instrument panel support structure.
  5. Install and tighten the nut (2) that secures the CTM mounting bracket to the instrument panel support structure. Tighten the nut securely.
  6. Reinstall the glove box module into the instrument panel. Refer to GLOVE BOX, INSTRUMENT PANEL, INSTALLATION .
  7. Connect the negative cable to the battery.
  8. Perform module PROXI configuration. (Refer to MODULE PROGRAMMING  ).