LEMON Manuals: Even more car manuals for everyone
Home >> Fiat >> 2016 >> 500 Turbo, Standard Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> (Heating & Air Conditioning - Electrical Diagnostics - 500 - Except Electric) >> DTC Troubleshooting >> B1906-77-Main/Left Temperature Door 1 - Commanded Position Not Reachable >> Diagnostic Test

Diagnostic Test

  1. CHECK FOR RELATED DTCS 
    1. Ignition on, engine not running.
    2. Using the scan tool, read HVAC DTCs.

      Are there any Blend Door Actuator Control or Sensor Control DTCs present?

      Yes 

      • Refer to DTC INDEX and perform the appropriate diagnostic procedure.

      No 

      • Go To  2
  2. CHECK IF DTC IS ACTIVE 
    1. Ignition on, engine running.
    2. Using the HVAC controls, switch to full hot and full cold and then back again.
    3. Using the scan tool, read HVAC DTCs.

      Is this DTC active?

      Yes 

      • Go To  3

      No 

      • Go To  5
  3. CHECK THE BLEND DOOR 
    1. Remove the Blend Door Actuator and check the Blend Door for binding and full travel. Refer to ACTUATOR, BLEND DOOR, REMOVAL .

      Were there any problems found?

      Yes 

      No 

      • Go To  4
  4. CHECK THE BLEND DOOR ACTUATOR 
    1. Turn the ignition off to the lock position.
    2. Replace the Blend Door Actuator in accordance with the Service Information. Refer to ACTUATOR, BLEND DOOR, REMOVAL .
    3. Reconnect all previously disconnected connectors.
    4. Ignition on, engine not running.
    5. Using the scan tool, erase HVAC DTCs.
    6. Using the scan tool, perform the HVAC Actuator Calibration Test.
    7. Turn the ignition off to the lock position for 30 seconds.
    8. Ignition on, engine running.
    9. Using the HVAC controls, switch to full hot and full cold and then back again.
    10. With the scan tool, read HVAC DTCs.

      Did this DTC reset?

      Yes 

      No 

      • Test complete.
  5. CHECK THE WIRING AND CONNECTORS 
    1. The conditions necessary to set the DTC are not present at this time.
    2. Using the scan tool, check the Environmental Data to help identify the conditions in which the DTC was set.
    3. Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
    4. Wiggle the wiring and connectors while checking for shorted and open circuits.

      Were there any problems found?

      Yes 

      No 

      • Test complete.