LEMON Manuals: Even more car manuals for everyone
Home >> Fiat >> 2016 >> 500 Turbo, Standard Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 8 ((Heating & Air Conditioning - Electrical Diagnostics - 500 - Electric)) >> DTC Troubleshooting >> B1909-11-RECIRCULATION Door Control - Circuit Short To Ground >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different variant/trim than selected.
  1. CHECK IF DTC IS ACTIVE 
    1. Ignition on, engine running.
    2. Using the HVAC controls, switch recirculation mode on and off several times.
    3. With the scan tool, read HVAC DTCs.

      Is this DTC active?

      Yes 

      • Go To  2

      No 

      • Go To  5
  2. CHECK THE (C32) RECIRCULATION DOOR DRIVER CIRCUIT FOR A SHORT TO GROUND 
    Fig 1: Checking Recirculation Door Driver Circuit For A Short To Ground
    GC0154176Courtesy of CHRYSLER GROUP, LLC
    1. Turn the ignition off to the lock position.
    2. Disconnect the A/C Heater Control harness connector.
    3. Disconnect the Recirculation Door Actuator harness connector.
    4. Measure the resistance between ground and the (C32) Recirculation Door Driver circuit.

      Is the resistance below 100k Ohms?

      Yes 

      • Repair the (C32) Recirculation Door Driver circuit for a short to ground.
      • Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST  .

      No 

      • Go To  3
  3. CHECK THE (C68) RECIRCULATION DOOR COMMON DRIVER CIRCUIT FOR A SHORT TO GROUND 
    Fig 2: Checking Recirculation Door Common Driver Circuit For A Short To Ground
    GC0154177Courtesy of CHRYSLER GROUP, LLC
    1. Measure the resistance between ground and the (C68) Recirculation Door Common Driver circuit.

      Is the resistance below 100k Ohms?

      Yes 

      • Repair the (C68) Recirculation Door Common Driver circuit for a short to ground.
      • Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST  .

      No 

      • Go To  4
  4. CHECK THE RECIRCULATION DOOR ACTUATOR 
    1. Turn the ignition off to the lock position.
    2. Replace the Recirculation Door Actuator in accordance with the Service Information. Refer to ACTUATOR, RECIRCULATION DOOR, REMOVAL .
    3. Reconnect all previously disconnected connectors.
    4. Ignition on, engine not running.
    5. Using the scan tool, erase HVAC DTCs.
    6. Using the scan tool, perform the HVAC Actuator Calibration Test.
    7. Turn the ignition off to the lock position for 30 seconds.
    8. Ignition on, engine running.
    9. Using the HVAC controls, switch recirculation mode on and off several times.
    10. With the scan tool, read HVAC DTCs.

      Did this DTC reset?

      Yes 

      No 

  5. CHECK THE WIRING AND CONNECTORS 
    1. The conditions necessary to set the DTC are not present at this time.
    2. With the scan tool, check the Environmental Data to help identify the conditions in which the DTC was set.
    3. Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
    4. Wiggle the wiring and connectors while checking for shorted and open circuits.

      Were there any problems found?

      Yes 

      No 

      • Test complete.