LEMON Manuals: Even more car manuals for everyone
Home >> Fiat >> 2016 >> 500 Turbo, Standard Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 8 ((Heating & Air Conditioning - Electrical Diagnostics - 500 - Electric)) >> DTC Troubleshooting >> B1906-11-Main/Left Temperature Door 1 Actuator Control - Circuit Short To Ground >> Set Condition

Set Condition

WARNING: This page is about a different variant/trim than selected.

The A/C Heater Control detects a short to ground on the Blend Door control circuit. If the A/C Heater Control detects valid current draw, the DTC will change from Active to Stored and will stay in the controllers memory for 100 ignition cycles.