LEMON Manuals: Even more car manuals for everyone
Home >> Fiat >> 2016 >> 500 Turbo, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 65 (1.4L 16-Valve Turbo - DTCS P1041-00 To P2101-00 - 500) >> DTC Troubleshooting >> P1128-00-Closed Loop Fueling Not Achieved - Bank 1 Upstream >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2015 Fiat 500. However, it is still accessible from the selected car via links, so may be relevant.
  1. ECT SENSOR OPERATION 
    NOTE:

    For this test to be valid, the thermostat must be operating correctly.

    NOTE:

    This test works best if performed on a cold engine (cold soak).

    1. Ignition on, engine not running.
    2. With the scan tool, read the Engine Coolant Temperature (ECT) Sensor value. If the engine was allowed to sit overnight (cold soak), the temperature value should be a sensible value that is somewhere close to the ambient temperature.
      NOTE:

      If engine coolant temperature is above 82°C (180°F), allow the engine to cool until 65°C (150°F) is reached.

    3. Start the Engine.
    4. During engine warm-up, monitor the ECT Sensor value. The temperature value change should be a smooth transition from start up to normal operating temperature 82° C (180° F). The value should reach at least 82° C (180° F).

      Did the ECT value increase smoothly and did it reach at least 82°C (180°F)?

      Yes 

      • Go To  2

      No 

  2. ACTIVE DTC 
    1. Diagnose all other DTCs before continuing.
    2. Start the engine.
    3. Allow the engine to reach normal operating temperature.
    4. With the scan tool, read DTCs.
      NOTE:

      It may be necessary to drive the vehicle to meet the conditions to set this DTC, try to repeat the conditions in which the fault originally set by reviewing the Freeze Frame data.

      Is the DTC Active or Pending at this time?

      Yes 

      • Go To  3

      No 

  3. CHECKING THE OXYGEN SENSOR OPERATION 
    1. Perform the CHECKING THE OXYGEN SENSOR OPERATION diagnostic procedure. Refer to DIAGNOSIS AND TESTING .

      Were any problems found?

      Yes 

      No 

      • Go To  4
  4. CHECKING FUEL PRESSURE 
    1. Perform the CHECKING THE FUEL DELIVERY SYSTEM test procedure. Refer to CHECKING THE FUEL DELIVERY SYSTEM (HARD START) .

      Were any issues found with the fuel system

      Yes 

      No 

      • Go To  5
  5. CHECKING THE MAP SENSOR OPERATION 
    1. Perform the diagnostic procedure for CHECKING THE MAP SENSOR OPERATION. Refer to CHECKING THE MAP SENSOR OPERATION .

      Were any problems found?

      Yes 

      No 

      • Go To  6
  6. CHECKING THE ENGINE MECHANICAL SYSTEM 
    1. Perform the diagnostic procedure for CHECKING THE ENGINE MECHANICAL SYSTEM. Refer to CHECKING THE ENGINE MECHANICAL SYSTEM .

      Were any problems found?

      Yes 

      No 

      • Go To  7
  7. O2 SENSOR 
    1. Turn the ignition off.
    2. Replace the O2 Sensor in accordance with the service information and reconnect the harness connector. Refer to SENSOR, OXYGEN, REMOVAL .
    3. Turn the ignition on.
    4. With the scan tool, erase DTCs.
    5. Start the engine and allow it to idle long enough for the O2 Sensor to enter closed loop operation.
    6. With the scan tool, view DTCs.

      Did the DTC return?

      Yes 

      • Go To  8

      No 

  8. POWERTRAIN CONTROL MODULE (PCM) 
    1. Using the wiring diagram/schematic as a guide, inspect the wiring and connectors between the related Sensors and the Powertrain Control Module (PCM).
    2. Look for any chafed, pierced, pinched or partially broken wires.
    3. Look for broken, bent, pushed out or corroded terminals. Verify that there is good pin to terminal contact in the related Sensor and Powertrain Control Module connectors.
    4. Perform any Technical Service Bulletins that may apply.

      Were there any problems found?

      Yes 

      No