Full Open Retractable Roof Relearn Procedure
If power retractable roof does not operate in the Auto Open/Close mode (automatically opening to the 1/4 open and 3/4 open comfort stops), or if the liftgate does not open, the following relearn procedure may be necessary:
- Confirm that the door/liftgate are closed.
- Begin with the top in the fully closed position (using manual mode).
- Hold the OPEN button to move the top to the fully open position.
- CONTINUE to hold the OPEN button for an additional three seconds.
- Release the OPEN button.
- Hold the CLOSE button to move the top to the fully closed position.
- CONTINUE to hold the CLOSE button until the top begins to cycle fully open, then release the CLOSE button.
At the end of Step 7 the top will automatically cycle to the fully open position and then close to the 1/4 open position. This will confirm that the relearn procedure was successful.
Auto Open/Close and liftgate operation will now be functional.
NOTE:
DO NOT interrupt this activity.
If the power retractable roof does not relearn repeat the procedure a second time.