LEMON Manuals: Even more car manuals for everyone
Home >> Fiat >> 2015 >> 500L Pop, Standard Trans >> Repair and Diagnosis >> Engine Mechanical >> Blowers, Superchargers & Turbochargers >> 1.4L Turbo Engine - (Service Information) - 500L >> Turbocharger System >> Solenoid, WASTEGATE >> Installation >> Installation

Solenoid, WASTEGATE: Installation: Installation

Fig 1: Wastegate Actuator Hose, Solenoid, Electrical Connector, Vacuum Supply Hose & Nut
GC0156333Courtesy of CHRYSLER GROUP, LLC
  1. Install the wastegate actuator (4).
  2. Install the nut (5). Tighten to 8 N.m (71 in. lbs.).
  3. Connect the vacuum hoses (1 & 2) and the electrical connector (3).
    Fig 2: Air Cleaner Assembly, Intake Hose, Fittings & Clamp
    GC0153787Courtesy of CHRYSLER GROUP, LLC
  4. Install the air cleaner assembly.
  5. Connect the two vacuum fittings (4), tighten the clamp (3) at the air to turbocharger inlet tube.
  6. Connect the fresh air intake hose (2).